1
$ sudo smartctl -a /dev/nvme1
smartctl 7.5 2025-04-30 r5714 [x86_64-linux-6.16.5-6.16-alt1] (ALT Sisyphus 7.5-alt1)
Copyright (C) 2002-25, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: KINGSTON SKC2500M82000G
Serial Number: 50026B7684E56FC3
Firmware Version: S7781101
PCI Vendor/Subsystem ID: 0x2646
IEEE OUI Identifier: 0x0026b7
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 2 000 398 934 016 [2,00 TB]
Namespace 1 Utilization: 1 759 042 101 248 [1,75 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 0026b7 684e56fc35
Local Time is: Fri Sep 19 18:35:07 2025 MSK
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0f): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.00W - - 0 0 0 0 0 0
1 + 4.60W - - 1 1 1 1 0 0
2 + 3.80W - - 2 2 2 2 0 0
3 - 0.0450W - - 3 3 3 3 2000 2000
4 - 0.0040W - - 4 4 4 4 6000 8000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 0
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02, NSID 0xffffffff)
Critical Warning: 0x00
Temperature: 37 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 1%
Data Units Read: 1 022 873 002 [523 TB]
Data Units Written: 37 086 892 [18,9 TB]
Host Read Commands: 4 371 833 838
Host Write Commands: 488 690 953
Controller Busy Time: 30 289
Power Cycles: 1 875
Power On Hours: 8 025
Unsafe Shutdowns: 42
Media and Data Integrity Errors: 348 158
Error Information Log Entries: 84
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Thermal Temp. 1 Transition Count: 428
Thermal Temp. 1 Total Time: 1186
Error Information (NVMe Log 0x01, 16 of 256 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 84 11 0xb224 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
1 83 11 0xa224 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
2 82 11 0x9224 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
3 81 11 0x8224 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
4 80 11 0x7224 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
5 79 11 0x6224 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
6 78 11 0xe223 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
7 77 11 0xd223 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
8 76 11 0xc223 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
9 75 11 0xb223 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
10 74 11 0xa223 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
11 73 11 0x9223 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
12 72 11 0x2222 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
13 71 11 0x1222 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
14 70 11 0x0222 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
15 69 11 0xf222 0x0281 - 482980992 1 - Unknown Command Specific Status 0x40
... (240 entries not read)
Self-test Log (NVMe Log 0x06, NSID 0xffffffff)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Completed: failed segments 8000 91898488 1 7 0x2 0x81
For immediate assistance, please email our customer support: [email protected]